• ademco 5853 manual

    ademco 5853 manual

    Download Link: ➡ ademco 5853 manual



    File Name: ademco 5853 manual.pdf
    Size: 3913 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 8 May 2019, 20:33 PM
    Rating: 4.6/5 from 615 votes.


    Last checked: 10 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download ademco 5853 manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    ademco 5853 manual

    Avoid mounti ng the d etector on the sam e wall a s the protected gla ss, on free-stan ding posts or pill ars, or i n rooms with no isy eq uipment (air compre ssors, bells, power tool s, etc.), if this equ ipm ent is oper ated when the detector i s armed. W all Mount (T op View) WallMnt-001-V0 CeilingMnt-001-V0 Ceiling Mount: (Side Vie w) NOTE: If the device is ce iling m ounted, the en d with t he hole (Microphone end) should f ace the protected glass. Enroll Detector Refer to text and co ntrol pa nel's in stallat ion instruct ions. Test Detector In stall ation Enter Test Mod e using a F lexGuard FG -701 Glassbrea k Simulator ( see Testin g the Dete ctor on t he next page). T o enter Te st Mo de manuall y, short the Test Mode pa ds (as show n below ). All R ights Re served Honeywell, FlexGuard and IntelliSense are registered trademarks of Honeywell Internati onal Inc. - All other brands mentioned are the trademarks or regist ered trademarks of their respectiv e owners. The se lf-cont ained det ector in clude s a transmitter that can send a larm s, tamper sig nals, a nd low battery message s to the control pan el. Refer to the f ollowing secti ons to in stall th e 5853. The detector will star t its power up sequenc e, in whi ch both t he LED in dicator s will illuminate for one second. (The LED in dicator s are described l ater in t hese instru ction s.) 3. Adjusting Detecto r Sen sitivity (Ran ge) The 5853 has four sensit ivity settin gs, which are set using the SENS1 a nd SENS2 DIP switche s. The settings are: 1) max imum; 2) medium; 3) l ow; and 4) lowest. By default, se nsitiv ity is se t to MAXIMU M. To change the detect or ’ s se nsi tivit y, use a small screwdriv er to adj ust the SEN S1 and SENS2 sw itches, as shown in the ta ble below: SENSIT IVITY A PPROX. RANGE SENS1 SENS2 MAX 7.6m (25 ft) OFF OFF MEDIUM 4.6m (15 ft) ON OFF LOW 3m (10 ft) OFF ON LOWEST 1.5m (5 ft) ON ON 4.

    • ademco 5853 manual, honeywell 5853 manual, ademco 5853 manual, ademco 5853 manual instructions, ademco 5853 manual download, ademco 5853 manual pdf, ademco 5853 manual user, ademco 5852 manual.

    The FlexCore TM signal processor utilizes an Application Specific Integrated Circuit (ASIC) - processing sound data in parallel rather than sequentially. This permits sound frequency, duration and amplitude to be analyzed 50% faster to minimize false alarms while maintaining the highest possible level of detection. The LEDs indicate test mode, alarms and trouble conditions. It is compatible with all 5800 series wireless devices. Product availability, at the moment, is in flux. If you order today, depending on the product, there may be a significant delay in shipping it to you. We apologize for any delays, and assure you that products will be shipped as soon as we can get them. Before COVID, we had significant stock of nearly every popular product that we sell. But demand has outpaced our supplier's ability to meet it, and has exhausted the stock we had purchased to meet increased demand during the government-mandated lockdowns. If you need the product right away, it is unlikely we will be able to accommodate you. For that we apologize. We ask for your patience as we all navigate this unique situation together. Be nice to our employees, they are doing their best to answer your questions and get your product to you as quickly as they can.If you are here to get product quickly because you are unable to get the product at your usual supplier, rest assured, we are also out of the product and won't be able to fulfill your order in a timely manner. Like our end-users, we will be delivering products as soon as we get them in. For help installing FlexGuard glass break sensors call us at 888-818-7728. Always verify range with a All Rights Reserved Honeywell, FlexGuard and IntelliSense are registered trademarks of Honeywell International Inc. - All other brands mentioned are the trademarks or registered trademarks of their respective owners.

    T he tamper screw m ust be se curel y mounted. Se e details on page 1. 3. If required by the mou nting l ocation, in stall wall anch ors for th e mounting screw s. 4. Secure the 5853 to the wall or ceiling, oriented so the micr ophone has the best l ine- of-sight to th e protect ed gla ss. 5. Reinstall the batt eries if pre viousl y removed. 6. Close and secure the detector front cover. 7. Testing t he Detect or The detector should be teste d at least once each ye ar. Test the dete ctor w ith the F lexGuard FG-701 Glassbr eak Simulator. O ther simul ators will not g ive ac curate indication of range. T he sim ulator buz zes a short activatio n code. When the dete ctor enter s Test Mode, th e green LED on the det ector flash es abo ut once per se cond. If the green LED do es not f lash, mo ve closer t o the det ector and repeat the procedur e. To enter Test Mode manuall y: 1. Open the front cover. 2. Use a scr ewdriver to short the Test Mod e pads on the PC board (se e dia gram on next page). 3. Close the front cover. The detector ’ s green LED bl inks appro ximate ly on ce per second to i ndicate that it has entered the test mode. Testing the Det ector (flex an d audio sign als): To test the 58 53, do th e follow ing: 1. Place the dete ctor in Test M ode. 2. Set the FG-701 switche s to th e TEST and FLEX position s. 3. Position the FG -701 n ear the f arthest point of the protected glass, and po int the s peaker directly at t he dete ctor. If win dow co verings are present, c lose them fully and hold t he FG-701 between the co vering s and the protected glass. 4. Press the red START button. The simulator clicks on and st arts an eigh t-secon d armed period. 5. Generate a fl ex sig nal by car ef ully str iking the glass wit h a cu shioned too l. The FG -701 responds with a burst of glass break aud io. If the detector receiv es both th e flex an d audio signals properly, its red Alarm LED lig hts for 5 seconds. (R ed Alarm LED does n ot latc h.

    Enrollin g Det ector In to 580 0-Series Receiv er Before the control p anel wil l recogniz e the 585 3, you must program the devic e's seri al number int o the control p anel. To tran smit th e number autom atically, mom entarily a ctivate the front tamper swi tch. To ente r the s erial num ber manual ly, refer to the co ntrol pan el ’ s inst ructions to enrol l the serial ID n umber which appear s on the product. 5. Select ing Install ation Locatio n The 5853 can be mou nted on t he ceiling or the w all. Choose a mou nting lo cation that is at least 2. 1m (7 feet) from floor and no m ore than 7.6m (25 feet) from the farthe st protec ted gla ss. B e sure the detect or has an unobstruc ted lin e-of-sight t o the prote cted gl ass. Before mountin g the det ector permanently, test it to ensure th at it fun ctions sat isfa ctorily in the chosen mounting lo cation. Verify t hat the de tector can detect glassbr eak sound s, follow ing t he dir ection s in the “ Testing t he Detect or ” sect ion. Ensur e that th e 5853 i s within rang e of the r eceiv er, follow ing the instructio ns for the signa l-strengt h test fo und in the co ntrol pan el ’ s install ation instr ucti ons. (To s end the sign al requir ed by the test, activat e the de tector' s front tamper switch.) If the detector fails, r elocat e it and re peat bot h tests. 6. Mounting the Detector NOTE: If using wa ll tamper a nd insta lling o n dry wal l (sheet rock), positi on the d etector so that t he wall tamper is o ver a wall stud or c eiling j oist, or use a drywall an chor so the tamper screw wil l not pu ll out. NOTE: If the de vice is c eiling m ounted, the end with the hole (Mi crophone en d) sho uld face the prote cted glass. To mount the detector: 1. Using the 5853 mount ing hol es as a tem plate, mark mounti ng loc ations on t he ce iling or wall. 2. If using the opt ional wall ta mper, remove the batteries, then m ark the w all tam per location thro ugh its mount ing hole.

    Recommendations must be included for a spe cific progra m of testing ( at least weekly) to ensure the syste m ’ s proper o peration at all times.PDF Version: 1.5. Linearized: No. Page Count: 2. Has XFA: No. XMP Toolkit: XMP toolkit 2.9.1-13, framework 1.6. About: uuid:3f7a906f-3386-4d9d-a898-619ace218be5. Producer: Acrobat Distiller 4.05 for Windows. Modify Date: 2009:03:09 09:13:06-04:00. Create Date: 2007:07:19 11:50:18Z. Metadata Date: 2009:03:09 09:13:06-04:00. Document ID: uuid:0ed2b0c8-78aa-4bf2-99e3-99ae9109ef65. Install Cover Screw (optional). Set Sensitivity (Range)Mounting Hole. Adjust. OrientationMicrophoneOrientationMounting HoleFront CoverRefer to text and control panel's installationBreak out flashWhen programming the transmitter, specify. Connect Batteries. Remove pull tab to connect batteries. Mount Detector. Adjust. Orientation. Wall. Use mounting holes as a template to markIf using the optional back tamper, removeMount detector using appropriate hardware. Close detector cover when finished.Orientation is. AdjustOrientation. Select Mounting Location. Optional Tamper Screw. Wall MountTest Detector Installation. Enter Test Mode using GBS-7 (see text). To enter. Test Mode manually, short Test Mode pads (as below). Avoid mounting withinPage 1Refer to Installation Instructions and diagrams (next page) when installing this productThe 5853 Wireless Glassbreak detector with. Transmitter senses the sound of breaking tempered,The selfcontained detector includes a transmitter that can sendNOTE: If using the rear tamper and installing on dryThe detector is equipped with two LEDs: a green Event. LED and a red Alarm LED. When the LEDs areTest Mode, and are inactive during normal operation.). NOTE: The 5853 is not recommended for protection ofPrior to installation, you must. Connect its batteries by removing the tab. Adjust the detector’s sensitivity, andRefer to the following sections to install the 5853.

    ) Testing the Det ector (audio signal s only): The FG-701 c an also be used to test th e detect or ’ s ability to receive aud io signal s only. See the FG-701 Operating In structi ons for addi tional i nformation. When it receives the audio signal, the dete ctor fli ckers its green Event LED. Exiting Test Mode: When you ha ve fini shed te sting, ex it Test Mod e by following the same pr ocedure used to enter Test M ode. The detector a utomati cally ex its Te st Mode five minu tes after the last event i s detected. 8. LED Indicators The detector i s equippe d with t wo LEDs: a green Event LED and a red Alarm LED. When the LED s are enabled duri ng testi ng, the y light in a variet y of pat terns to convey t he dete ctor ’ s o perationa l status. The install er shoul d inform the end user that fans, a ir conditioner s, blow ers, l oudspe akers, or other so urces of vibration and sou nd should not be introdu ced into the protected area after instal lation of glassbreak detectors. NOTIC ES FCC NOTICE This device complies with P art 15 of the FCC rules and R SS 210 of Industry Canad a. Operation is s ubject to th e following two co nditions: (1) This device may not cause harmful inte rference, and (2) this device must accept any interference receiv ed, including int erference t hat may cause un desired oper ation. Unauthorized chan ges or modificati ons could void the user's a uthority to operate the equipment. TO THE INS TA LLER Regular maintena nce and inspection (at least annually) by the instal ler and fre quent testing by the user are vit al to continuous sa tisfactory operatio n of any alar m system. The installer should assume the responsibility of developin g and offering a r egular maintenance progra m to the use r as well as ac quainting the use r with the prop er operation and limitations of the alarm syst em and its com ponent parts.

    We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service.\u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Our technicians will send you the pre-program form via email for you to fill out so that they know how you want your system setup.We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service.You can have our technicians pre-program and setup your system prior to it shipping. Our technicians will send you the pre-program form via email for you to fill out so that they know how you want your system setup. This will delay shipping 1-3 days after we receive your pre-program form.Our pre-programming service includes: Setting up and enrolling sensors as desired Custom labeling alpha keypads Setting entry and exit delays Setting up user codes and authority levels Setting communications and call out numbers for self-monitoring Testing and verifying your system before shipping This is a great way to get your.We even provide simplified quick.For those without the time or inclination to learn how to program them, we offer this optional pre-programming service.\u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Our technicians will send you the pre-program form via email for you to fill out so that they know how you want your system setup. We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service.

    \u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Our technicians will send you the pre-program form via email for you to fill out so that they know how you want your system setup.The 4120TR is a wiring harness that will connect to the trigger pins via a plug. These have many uses. These are most commonly used for resetting 4-wire smoke detectors. The 4120TR is a wiring harness that will connect to the trigger pins via a plug. These have many uses.The Honeywell 4120TR is a trigger cable that is used to trigger certain programmed events using a Honeywell Vista trigger output pins. These are most commonly used for resetting 4-wire smoke detectors. The 4120TR is a wiring harness that will connect to the trigger pins via a plug. These have many uses. If you have any questions as to the workings of the 4120TR then please give our tech support specialists a call to inquire.The 4120TR is a wiring harness that will connect to the trigger pins via a plug. These have many uses. These are most commonly used for resetting 4-wire smoke detectors. The 4120TR is a wiring harness that will connect to the trigger pins via a plug. These have many uses.You can attach this probe to a 5821 and put this anywhere that you need flood detection.The 470PB is an add-on for the Honeywell 5821. You can attach this probe to a 5821 and put this anywhere that you need flood detection. Great for uses in basements, bathrooms, etc. Specifications:You can attach this.You can attach this probe to a 5821 and put this anywhere that you need flood detection. Glass Break 5 051 735 00A 5853 new T he self- containe d detector i nclude s a t ransmitter th at can send alarms, tam per sign als, and l ow batter y mes sages to the control p anel. Refer to th e Protect ed Glass Types section and chart for complete inform ation. The detector will star t its power up sequenc e, in whi ch both t he LED in dicator s will illuminate for one second.

    The 5853 has four sensitivity settings, which are setBefore the control panel will recognize the 5853, youWhen programming the transmitter, specify. You can transmit the device’s serial numberTo transmit theID number which appears on the product.The 5853 can be mounted on the ceiling or the wall. Choose a mounting location that is at least 7 feetBe sure the detector hasBefore mounting the detector permanently, test it toEnsure that the 5853 isIf the detector fails, relocate it and repeat both tests. Add: When ceiling mounted, the microphoneON 1 second. ON 1 second. Test Mode. Flash once per secFlickerFlash once per sec. ON 5 seconds. Flash once per sec. Flash once per secThe front cover can be secured after installation. To doHow long after firstThe detector should be tested at least once each year. Test the detector with the GBS-7 Glassbreak Simulator. Other simulators will not give accurate indication ofTo maintain the 5853 Glassbreak DetectorTo test, you must first place the detector in test mode. To connect the batteries, remove the tab from the endThe detector will start its powerTo mount the detector:Replace the batteries when the system indicates a lowThis device should not be relocated without the adviceFans, air conditioners, blowers, loudspeakers, or otherIf unavoidable, contact the alarmTo enter the test mode manually, do the following. To enter Test Mode manually:The detector’s green LED blinks approximately once perTo enter the Test Mode with the GBS-7:START button. The simulator buzzes a shortNOTE: The 5853 is NOT recommended for protection of glass. When the detector enters Test Mode, the green LEDTesting the Detector (flex and audio signals). To test the 5853, do the following:FLEX positions.The simulatorIf the detector receives both the flex and audio signalsAlarm LED does not latch.). Plate 3. Tempered. Laminated1. Wired. Coated2 2,3. Sealed Insulating11,3. Nominal Thickness. Minimum. MaximumProtected only if both plates in the unit are broken.

    Coated glass with security films, including films for solar protection, upGARD GLL 1200 has been evaluated with this product by. Underwriters Laboratories Inc.Add Note 3Power. Two 3 V Batteries (included).Varta CR123A (Lithium Manganese Dioxide) Expected battery. Exiting Test Mode. When you have finished testing, exit Test Mode byThe detector automatically exits Test Mode after fiveCanada's Standard for Intrusion Detection UnitsFlexGuard is a registered trademark of Honeywell, Inc. - All otherSpecifications subject to changeMaximum range is 25 ft (7.6m) from farthest protected glass. No minimum range. Missing Specs. Operating Temperature. Testing the Detector (audio signals only). The GBS-7 can also be used to test the detector’sSee the GBS-7. Operating Instructions for additional information. WhenAre these for endAccessories:Operation is subject to theRecommendations must be included for aPDF Version: 1.3. Linearized: No. Create Date: 2002:03:04 15:26:34. Producer: Acrobat Distiller 4.05 for Windows. Creator: PSCRIPT.DRV Version 4.0. Modify Date: 2002:04:09 09:27:11-07:00. Page Count: 2. Has XFA: No. This particular detector has a Flex Core signal processor which will.This particular detector has a Flex Core signal processor which will process sound data in parallel rather than sequentially. This processing will provide fewer false alarms. Honeywell 5853 Glass Break has LED's that will indicate alarm, trouble, and test mode conditions. The Ademco 5853 can be mounted on a ceiling or wall. This glass break detector is compatible with a 5800 series alarm system by Honeywell, Ademco, and Lynx. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service.\u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Our technicians will send you the pre-program form via email for you to fill out so that they know how you want your system setup.

    (The LED in dicator s are described l ater in t hese instru ction s.) 3. Adjusting Detecto r Se nsitivity (Ran ge) The 5853 has four sensit ivity settin gs, which are set usi n g t h e SE N S1 a nd SE N S2 D IP s w it c h e s The se t t in g s a r e: 1) m axi m u m; 2) m e d i u m; 3) low; and 4) lowest. B y default, sen sitivit y is set t o MAXIMUM. To chang e the det ector’ s sensi tivity, use a sm all screwdriv er to adjust the SEN S1 and SENS2 sw itches, as shown in the ta ble below: SENSIT IVITY A PPROX. To tran smit th e number autom atically, mom entarily acti vate the front tamper swit ch. To ente r the s erial num ber manual ly, refer to the co ntrol pan el’s inst ructions to enroll th e seria l ID number wh ich app ears on t he produc t. 5. Select ing Install ation Locatio n The 5853 can be mou nted on t he ceiling or the w all. Choose a mou nting lo cation that is at least 7 feet (2.1m) from flo or and no m ore than 2 5 feet (7.6m ) from the farthe st protec ted glass. B e sure the detect or has an unobstruc ted lin e-of-sight t o the prote cted gl ass. Before mountin g the det ector permanently, test it to ensure th at it fun ctions sat isfa ctorily in t he cho sen mounting lo cation. Verify t hat the de tector can detect glassbr eak sound s, follow ing t he direct ions i n the “Testing the D etect or” section. Ensur e that the 58 53 is within rang e of the r eceiv er, follow ing the in structio ns for the signa l-strengt h test fo und in the co ntrol pan el’s install ation instr uction s. (To send th e sign al requir ed by the test, activat e the de tector' s front tamper switch.) If the detector fails, r elocat e it and repeat both te sts. 6. Mounting the Detector NOTE: If using the r ear tamp er and in stalling on dry w all ( s he e t r o ck), p o sit i on t he det e c tor so t hat t he wall tamper is o ver a wall stud or c eiling j oist. To mount the detector: 1.

    Using the 5853 mount ing hol es as a tem plate, mark mounti ng loc ations on t he ce iling or wall. 2. If using t he op t ional wall t a mper, re m o v e the b a tter i es, th e n m a rk t he wal ta m per location thro ugh its mount ing hole. 3. If required by the mou nting loc ation, in stall wall anch ors for th e mounting screw s. 4. Secure the 5853 to the wall or ceiling, orien t ed so t he m ic r op h one h a s the b e st line-o f - s i ght t o t h e pr o t e c ted gl a ss. 5. Reinstall the batt eries if pre viousl y removed. 6. Close and secure the detector front cover. 7. Testing t he Detect or The detector should be teste d at least once each ye ar. Test the dete ctor w ith the GBS -7 Glas sbreak S imulator. Other simu lators wi ll not give accur ate ind ication of range. To enter Test Mode manuall y: 1. Open the front cover. 2. Use a scr ewdriver to short the Test Mod e pads on the PC board (se e dia gram on next page). 3. Close the front cover. The detector ’ s green LED blin ks appro ximate ly on ce per second to i ndicate that it has entered the test mode. To enter the Te st Mode with the GBS-7: 1. Stand within 4.6 m (15 fe et) of the detector. 2. Switch the GBS-7 t o ACTIVAT E and MANual modes. 3. Point the fr ont of th e glassbre ak simu lator towards the detector an d pres s the red START button. The simul ator buz zes a short activat ion code. When the dete ctor enter s Test Mode, th e green LED on the det ector flash es abo ut once per se cond. If the green LED do es not f lash, mo ve closer t o the det ector and repeat the procedur e. Testing the Det ector (flex an d audio sign als): To test the 58 53, do th e follow ing: 1. Place the dete ctor in Test Mod e. 2. Set the GBS-7 sw itches t o the TEST and FLEX position s. 3. Position the G BS-7 near the fa rthest po int of the protected glass, and po int i t directl y at the detector.

    If w indow c overings are presen t, close them fully and hol d the G BS-7 between the covering s and t he prote cted gla ss. 4. Press the red START button. The simulator clicks on and st arts an eigh t-secon d armed period. 5. Generate a fl ex sig nal by car ef ully strik ing the glass wit h a cu shioned too l. The G BS-7 responds with a burst of glass break aud io. If the detector receives both th e flex an d audio signals properly, its red Alarm LED lig hts for 5 seconds. (R ed Alarm LED does n ot latc h.) Testing the Det ector (audio signal s only): The GBS-7 can also be used to tes t the det ector ’ s ability to re ceive audio signal s only. See the GBS-7 Operating In structi ons for addi tional i nformation. When it receives the audio signal, the dete ctor fli ckers its green Event LED. Exiting Test Mode: When you ha ve fini shed te sting, ex it Test Mod e by following the same pr ocedure used to enter Test M ode. The detector a utomati cally ex its Te st Mode after fi ve minutes if no event s are de tected. 8. LED Indicators The detector i s equippe d with t wo LEDs: a green Event LED and a red Alarm LED. When the LED s are enabled duri ng testi ng, the y light in a variet y of pat terns to convey t he dete ctor ’ s o perationa l status. This devic e shou ld not be rel ocate d without t he adv ice or assistan ce of th e alarm service compa ny. Fans, air condition ers, blow ers, loudspeak ers, or ot her sources of vibr ation and s ound should not be introduced i nto the pr otected area aft er installa tion of glassbreak detecto rs.NOTIC ES F CC NO T I C E F CC I D: C F S 8 D L 5853-1 This device complies wi th Part 15 of FCC rules. Oper ation is subject to the following tw o condi tions: (1) This de vice m ay not caus e harmful inter ference, and (2) this device m ust acce pt any i nterfer ence received, i ncluding interferen ce that may cause undes ired o peration.

    CANADA: 1748A-58531 TO THE INSTALLER R e gular m a i n ten a nce and in s p e c ti o n ( a t l e ast a n n u ally) by the installer and f r equ e nt t est i ng by t h e user a r e vi t a l t o c o nti n u o us s a tis f ac t o r y operation of a n y ala r m sy s te m. T h e i n stal l er s h o u ld a s s u m e t h e r es p o n s i b ility o f developi ng and offer ing a regular mainte nance pr ogram to the user as well as acquainti ng the user wi th the proper o pera tion an d limitati ons of the alarm system and it s compone nt par ts. Recom mendatio ns must be i nclude d for a specific pro gram of t esting (at least weekly) to ensure the system ’s pro per operati on at all times. To test, you must first place the detector in test mode. The 5853 can be mounted on any wall or ceiling within a 25' range, with no minimum range limitation. The LEDs indicate test mode, alarms and trouble conditions. It is compatible with all 5800-Series wireless devices. The 5853 wireless glassbreak detector with transmitter senses the sound of breaking plate, tempered, laminated, wired, coated, and sealed insulating glass. The self-contained detector includes a transmitter that can send alarms, tamper signals, and low battery messages to the control panel. The sensor is compatible with 5800-series wireless hardware, and is designed for continuous operation using one 3V lithium battery (CR-123A or equivalent; included). Choose a mounting location that is at least 2.1 (7 feet) from floor and no more than 7.6m (25 feet) from the farthest protected glass. Be sure the detector has an unobstructed line-of-sight to the protected glass. Before mounting the detector permanently, test it to ensure that it functions satisfactorily in the chosen mounting location. Ensure that the 5853 is within range of the receiver, following the instructions for the signal-strength test found in the control panel's installation instructions. If the detector fails, relocate it and repeat both tests.

    Product Features: Test mode can be activated remotely with FG-701 Tester It was easy to install and program. Great company!!! Was this rating helpful to you. Installation Manual Data Sheet Availability It offers four adjustable sensitivity settings as well as built in false alarm protection to provide reliable detection of breaking glass. Keep in mind that as an audio detection device, the 5853 must more or less face the protected glass and have uninterrupted line of sight in order for full proper functionality. Installation where intervening walls or other blockage exists between the detector and the glass will not allow proper function.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :